932 research outputs found

    Branching fractions and charge asymmetries in charmless hadronic B decays at BaBar

    Get PDF
    We present measurements of branching fraction and charge asymmetry in charmless hadronic B decays with η and η mesons in the final state. All results use the final BaBar dataset corresponding to 465 × 106 BB pairs

    Analysis of heavy spin--3/2 baryon--heavy spin--1/2 baryon--light vector meson vertices in QCD

    Get PDF
    The heavy spin--3/2 baryon--heavy spin--1/2 baryon vertices with light vector mesons are studied within the light cone QCD sum rules method. These vertices are parametrized in terms of three coupling constants. These couplings are calculated for all possible transitions. It is shown that correlation functions for these transitions are described by only one invariant function for every Lorenz structure. The obtained relations between the correlation functions of the different transitions are structure independent while explicit expressions of invariant functions depend on the Lorenz structure.Comment: 17 Pages, 6 Figures and 4 Table

    Comparison Between Diffusion-Weighted MRI and I-123-mIBG Uptake in Primary High-Risk Neuroblastoma

    Get PDF
    Background: High-risk neuroblastoma (HR-NB) has a variable response to preoperative chemotherapy. It is not possible to differentiate viable vs. nonviable residual tumor before surgery. Purpose: To explore the association between apparent diffusion coefficient (ADC) values from diffusion-weighted magnetic resonance imaging (DW-MRI), 123I-meta-iodobenzyl-guanidine (123I-mIBG) uptake, and histology before and after chemotherapy. Study Type: Retrospective. Subjects: Forty patients with HR-NB. Field Strength/Sequence: 1.5T axial DW-MRI (b = 0,1000 s/mm2 ) and T2-weighted sequences. 123I-mIBG scintigraphy planar imaging (all patients), with additional 123I-mIBG single-photon emission computed tomography / computerized tomography (SPECT/CT) imaging (15 patients). Assessment: ADC maps and 123I-mIBG SPECT/CT images were coregistered to the T2-weighted images. 123I-mIBG uptake was normalized with a tumor-to-liver count ratio (TLCR). Regions of interest (ROIs) for primary tumor volume and different intratumor subregions were drawn. The lower quartile ADC value (ADC25prc) was used over the entire tumor volume and the overall level of 123I-mIBG uptake was graded into avidity groups. Statistical Tests: Analysis of variance (ANOVA) and linear regression were used to compare ADC and MIBG values before and after treatment. Threshold values to classify tumors as viable/necrotic were obtained using ROC analysis of ADC and TLCR values. Results: No significant difference in whole-tumor ADC25prc values were found between different 123I-mIBG avidity groups pre- (P = 0.31) or postchemotherapy (P = 0.35). In the “intratumor” analysis, 5/15 patients (prechemotherapy) and 0/14 patients (postchemotherapy) showed a significant correlation between ADC and TLCR values (P < 0.05). Increased tumor shrinkage was associated with lower pretreatment tumor ADC25prc values (P < 0.001); no association was found with pretreatment 123I-mIBG avidity (P = 0.17). Completely nonviable tumors had significantly lower postchemotherapy ADC25prc values than tumors with >10% viable tumor (P < 0.05). Both pre- and posttreatment TLCR values were significantly higher in patients with >50% viable tumor than those with 10–50% viable tumor (P < 0.05). Data Conclusion: 123I-mIBG avidity and ADC values are complementary noninvasive biomarkers of therapeutic response in HR-NB. Level of Evidence: 4. Technical Efficacy Stage: 3

    The Future of Neutrino Mass Measurements: Terrestrial, Astrophysical, and Cosmological Measurements in the Next Decade. Highlights of the NuMass 2013 Workshop. Milano, Italy, February 4 - 7, 2013

    Full text link
    The third Workshop of the NuMass series ("The Future of Neutrino Mass Measurements: Terrestrial, Astrophysical, and Cosmological Measurements in the Next Decade: NuMass 2013") was held at Dipartimento di Fisica "G. Occhialini, University of Milano-Bicocca in Milano, Italy, on 4-7 February 2013. The goal of this international workshop was to review the status and future of direct and indirect neutrino mass measurements in the laboratory as well as from astrophysical and cosmological observations. This paper collects most of the contributions presented during the Workshop

    Response of a TeO_2 bolometer to alpha particles

    Full text link
    TeO2TeO_2 crystals are used as bolometers in experiments searching for Double Beta Decay without emission of neutrinos. One of the most important issues in this extremely delicate kind of experiments is the characterization of the background. The knowledge of the response to α\alpha particles in the energy range where the signal is expected is therefore a must. In this paper we report the results on the response function of a TeO2TeO_2 bolometer to α\alpha's emitted by 147^{147}Sm dissolved in the crystal at the growth phase. A Quenching Factor of (1.0076±0.00051.0076\pm 0.0005) is found, independent of the temperature in the investigated range. The energy resolution on α\alpha peaks shows a standard calorimeter energy dependence: σ  [keV]=(0.56±0.02)(0.010±0.002)E[keV]\sigma\; [\rm{keV}] = (0.56 \pm 0.02) \oplus (0.010 \pm 0.002)\sqrt{E[\rm{keV}]} . Signal pulses show no difference between α\alpha and βγ\beta\gamma particle

    The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors

    Get PDF
    The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest bolometric mass ever operated. The experiment will work at a temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free system based on pulse tubes and a custom high power dilution refrigerator, designed to match these specifications. The cryostat has been commissioned in 2014 at the Gran Sasso National Laboratories and reached a record temperature of 6 mK on a cubic meter scale. In this paper, we present results of CUORE commissioning runs. Details on the thermal characteristics and cryogenic performances of the system will be also given.Comment: 7 pages, 2 figures, LTD16 conference proceedin

    Variation in Glycemic Outcomes in Focal Forms of Congenital Hyperinsulinism - The UK Perspective

    Get PDF
    Context: In focal congenital hyperinsulinism (CHI), localized clonal expansion of pancreatic β-cells causes excess insulin secretion and severe hypoglycemia. Surgery is curative, but not all lesions are amenable to surgery. Objective: We describe surgical and nonsurgical outcomes of focal CHI in a national cohort. Methods: Patients with focal CHI were retrospectively reviewed at 2 specialist centers, 2003-2018. Results: Of 59 patients with focal CHI, 57 had heterozygous mutations in ABCC8/KCNJ11 (51 paternally inherited, 6 de novo). Fluorine-18 L-3,4 dihydroxyphenylalanine positron emission tomography computed tomography scan identified focal lesions in 51 patients. In 5 patients, imaging was inconclusive; the diagnosis was established by frozen section histopathology in 3 patients, a lesion was not identified in 1 patient, and 1 declined surgery. Most patients (n = 56) were unresponsive to diazoxide, of whom 33 were unresponsive or partially responsive to somatostatin receptor analog (SSRA) therapy. Fifty-five patients underwent surgery: 40 had immediate resolution of CHI, 10 had persistent hypoglycemia and a focus was not identified on biopsy in 5. In the 10 patients with persistent hypoglycemia, 7 underwent further surgery with resolution in 4 and ongoing hypoglycemia requiring SSRA in 3. Nine (15% of cohort) patients (1 complex surgical access; 4 biopsy negative; 4 declined surgery) were managed conservatively; medication was discontinued in 8 children at a median (range) age 2.4 (1.5-7.7) years and 1 remains on SSRA at 16 years with improved fasting tolerance and reduction in SSRA dose. Conclusion: Despite a unifying genetic basis of disease, we report inherent heterogeneity in focal CHI patients impacting outcomes of both surgical and medical management

    CUPID-0: the first array of enriched scintillating bolometers for 0decay investigations

    Get PDF
    The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of82Se neutrinoless double-beta decay (0). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0at the level of 10- 3 counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn82Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here

    First array of enriched Zn82^{82}Se bolometers to search for double beta decay

    Get PDF
    The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in 82^{82}Se, the Zn82^{82}Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn82^{82}Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0
    corecore